McQuay MWSS Průvodce řešením problémů Strana 1

Procházejte online nebo si stáhněte Průvodce řešením problémů pro Split-systém klimatizace McQuay MWSS. McQuay MWSS Troubleshooting guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - GUIDE BOOK

SERVICEGUIDE BOOK

Strany 2 - Table of Contents

MCQUAY Service Guide Book Handset Operati

Strany 3 - 1.0 MODEL NAME

MCQUAY Service Guide Book Handset Operati

Strany 4 - 2.0 CONVERSION TABLE

MCQUAY Service Guide Book Handset Operati

Strany 5 - Netware 3C

MCQUAY Service Guide Book Handset Operati

Strany 6

MCQUAY Service Guide Book Handset Operati

Strany 7 - 4.0 HANDSET OPERATING GUIDE

MCQUAY Service Guide Book Handset Operati

Strany 8 - Operation Guide

MCQUAY Service Guide Book Handset Operati

Strany 9 - 4.3 G11

MCQUAY Service Guide Book Handset Operati

Strany 10 - 4.4 G17

MCQUAY Service Guide Book Handset Operati

Strany 11 - 4.5 GS01

MCQUAY Service Guide Book Handset Operati

Strany 12

MCQUAY Service Guide Book Table of Contents 1 Table of Contents 1.0 MODEL NAME 1.1 Product Name Description ...

Strany 13 - 4.6 APJ1

MCQUAY Service Guide Book Handset Operati

Strany 14

MCQUAY Service Guide Book Handset Operati

Strany 15 - 4.7 SLM3

MCQUAY Service Guide Book Handset Operati

Strany 16 - 4.8 SLM8

MCQUAY Service Guide Book Handset Operati

Strany 17

MCQUAY Service Guide Book Handset Operati

Strany 18 - 4.9 Netware 3 / Netware 3C

MCQUAY Service Guide Book Handset Operati

Strany 19

MCQUAY Service Guide Book Handset Operati

Strany 20 - 4.10 Rooftop Panel

MCQUAY Service Guide Book Controller Configuration 26 5.0 CONTROLLER SETTING 5.1 Auto Random Restart 5.2 Hot Keep Selection • Shorted

Strany 21 - Operating Guide

MCQUAY Service Guide Book Controller Configuration 27 L2 Models Two selections are available: a. Fan ON: - If the indoor coil tempera

Strany 22 - 4.11 Chiller Panel

MCQUAY Service Guide Book Controller Configuration 28 5.3 Sequential Board (SQ2.0) Dip switch setting of sequential controller are as the

Strany 23 - 4.12 MC301

MCQUAY Service Guide Book Model Name 2 1.0 MODEL NAME 1.1 Product Name Description No. Description Generic Model Name MCQUAY

Strany 24

MCQUAY Service Guide Book Controller Configuration 29 6. Defrost Option Select whether compressor will turn off or remain on when 4WV chan

Strany 25 - 4.13 MC303

MCQUAY Service Guide Book Controller Configuration 30 5.4 Chilled Water Fan Coil Unit (W1V3) The standard W1V3 board comes with a VALVE ju

Strany 26

MCQUAY Service Guide Book Controller Configuration 31 5.5 Chilled Water Fan Coil Unit (W2.0) The system operating modes can be configured

Strany 27 - 5.0 CONTROLLER SETTING

MCQUAY Service Guide Book Controller Configuration 32 5.6 Hardware Setting – SLM8 There are 2 jumpers on SLM8 option to control the board

Strany 28 - L208A / LWS2.0 models

MCQUAY Service Guide Book Controller Configuration 33 6.0 CONVERSION CONFIGURATION 6.1 Auxiliary Heater Conversion U1.5 Heatpump with Aux

Strany 29 - 5.3 Sequential Board (SQ2.0)

MCQUAY Service Guide Book Controller Configuration 34 SB125 Heatpump with Auxiliary Heater To convert SB125 heatpump PCB to auxiliary heat

Strany 30

MCQUAY Service Guide Book Controller Configuration 35 W2 Heatpump with Auxiliary heater To convert SB125 heatpump PCB to auxiliary heater

Strany 31

MCQUAY Service Guide Book Controller Configuration 36 6.2 Multi Split Conversion Cooling Only Model (L2.0 / L208A) MWM-G, MCK-A/B/C/E, MC

Strany 32

MCQUAY Service Guide Book Controller Configuration 37 6.3 U1.5 Æ L208A Conversion All single split indoor units with U1.5 PCB cannot be di

Strany 33

MCQUAY Service Guide Book Controller Configuration 38 6.4 WMF U1.4 to L2EF Conversion 1. The U1.4 PCB can be replaced directly by the new

Strany 34 - 6.0 CONVERSION CONFIGURATION

MCQUAY Service Guide Book Conversion Table 3 2.0 CONVERSION TABLE 2.1 Conversion Table Capacity Btu/hr MBH kCal/Hr kW 1 0.001

Strany 35

MCQUAY Service Guide Book Controller Configuration 39 6.5 SQ Board for Wiring up to 1000m Conversion Comparison of Sequential Main Board S

Strany 36 - 2. JM Relay 240VAC/ 20A

MCQUAY Service Guide Book Controller Configuration 40 Sequential LCD conversion for wiring up to 1000m Work Indication (WI): Step 1: Dism

Strany 37 - 6.2 Multi Split Conversion

MCQUAY Service Guide Book Controller Configuration 41 6.6 Room Sensor on Netware 3 There is a temperature sensor located at TH1 on the Ne

Strany 38 - U1.5 Æ L208A Conversion

MCQUAY Service Guide Book Diagnosis 42 7.0 SERVICE DIAGNOSIS 7.1 LED Lights Diagnosis Table Wall Mounted F Series Cooling Only Model

Strany 39

MCQUAY Service Guide Book Diagnosis 43 Wall Mounted F Series Heat Pump Model Board Handset MWM 10/15/20/25FR, 301R U1.5 G7 / SLM3

Strany 40 - IC:MAX1483

MCQUAY Service Guide Book Diagnosis 44 Wall Mounted G Series Model Board Handset MWM 10/15/20/25G/GR L2.2 G17 / SLM3 / Netware 3 /

Strany 41

MCQUAY Service Guide Book Diagnosis 45 Wall Mounted J Series Model Board Handset MWM 09/15J/JR L2GSN G17 SLEEP (Red) POWER

Strany 42 - 6.6 Room Sensor on Netware 3

MCQUAY Service Guide Book Diagnosis 46 Ceiling Cassette A / B / C Series Model Model Board Handset MCK 20/25/30/40/50A/AR U1.5 G7 /

Strany 43 - 7.0 SERVICE DIAGNOSIS

MCQUAY Service Guide Book Diagnosis 47 Ceiling Cassette A / B / C/ E Series Model Model Board Handset MCK 20/25/30/40/50A/AR L208A G

Strany 44 - (Green)

MCQUAY Service Guide Book Diagnosis 48 Ceiling Exposed D Series Model Model Board Handset MCM 20/25/30/40/50D/DR U1.5 G7 / SLM3 / N

Strany 45 - Wall Mounted G Series

MCQUAY Service Guide Book

Strany 46 - Wall Mounted J Series

MCQUAY Service Guide Book Diagnosis 49 Ceiling Exposed D / E Series Model Model Board Handset MCM 20/25/30/40/50D/DR L208A G17 / S

Strany 47

MCQUAY Service Guide Book Diagnosis 50 Chilled Water Fan Coil Unit Model Board Handset MWM 05 – 25FW, 301W W1V3 G7 / SLM3 / Netware

Strany 48

MCQUAY Service Guide Book Diagnosis 51 Water Source Split Unit – Wall Mounted G Series Model Model Board Handset M5WMWS 10/15/20/25GR

Strany 49

MCQUAY Service Guide Book Diagnosis 52 Water Source Split Unit – Ceiling Cassette A / B / C Series Model Model Board Handset M5CKWS

Strany 50

MCQUAY Service Guide Book Diagnosis 53 Wall Mounted F Cooling Only Inverter-X Model Model Board Handset MWMX 10/15F VA2.0 G17 / SLM

Strany 51 - Chilled Water Fan Coil Unit

MCQUAY Service Guide Book Diagnosis 54 Wall Mounted F Heatpump Inverter-X Model Model Board Handset MWMX 10/15FR VA2.0 G17 / SLM3

Strany 52

MCQUAY Service Guide Book Diagnosis 55 Wall Mounted G Series Inverter-X Model Model Board Handset MWMX 10/15/20/25G/GR VA2.0 G1

Strany 53

MCQUAY Service Guide Book Diagnosis 56 Ceiling Cassette A/C Series Inverter-X Model Model Board Handset MCKX 20/25A/AR VA3.0 G17 /

Strany 54

MCQUAY Service Guide Book Diagnosis 57 Ceiling Convertible E Series Inverter-X Model Model Board Handset MCMX 15/20/25E/ER VA3.0 G

Strany 55

MCQUAY Service Guide Book Diagnosis 58 Inverter - X Outdoor Unit Model Board MLCX 10/15/20/25C/CR VB2.0 MMSV 25/35A VB2.0 AMSX 20/2

Strany 56 - (Orange)

MCQUAY Service Guide Book

Strany 57

MCQUAY Service Guide Book Diagnosis 59 Inverter-Y Model Indoor Series Model Board Handset M5WMY 10/15/20/25 JR W_2_03A GS01 / G17

Strany 58 - 6 times

MCQUAY Service Guide Book Diagnosis 60 Single Split Inverter – Y Outdoor Unit Model Board M5LCY 10/15 DR S_2_03A M5LCY 20/25 CR S

Strany 59 - Inverter - X Outdoor Unit

MCQUAY Service Guide Book Diagnosis 61 Multi Split Inverter – Y Outdoor Unit Model Board M5MSY 20/25/30 BR - The outdoor unit LE

Strany 60

MCQUAY Service Guide Book Diagnosis 62 7.2 Error Codes Diagnosis By Handset SLM 3 / Netware 3 / SLM 9 – On/Off Models Error Code Fa

Strany 61

MCQUAY Service Guide Book Diagnosis 63 Netware 3C / SLM 9 – Inverter Y Models (Except 5WMY-J/JR) Error Code Faulty Indication Error Co

Strany 62

MCQUAY Service Guide Book Diagnosis 64 Sequential Controller (SQ LCD) – SB & RT Multi Compressors Error Code Faulty Indication Err

Strany 63 - SLM 3 – Inverter X Models

MCQUAY Service Guide Book Diagnosis 65 Rooftop Panel Alarm Shown On The Rooftop Panel • Whenever panel received a new alarm, an alarm

Strany 64

MCQUAY Service Guide Book Diagnosis 66 Condenser fan motor faulty Replace fan motor. Main PCB faulty Replace main PCB. 9. Disconnecti

Strany 65

MCQUAY Service Guide Book Diagnosis 67 Chiller Panel – Air Cooled Mini Chiller When malfunctioning occurred, the display LCD will blin

Strany 66 - Rooftop Panel

MCQUAY Service Guide Book Diagnosis 68 G17 – Inverter Y Models Diagnosis Step 1. Hold down TIMER CANCEL button for 5 seconds, a “

Strany 67

MCQUAY Service Guide Book Handset Opera

Strany 68

MCQUAY Service Guide Book Diagnosis 69 GS01 – Inverter Y Models Diagnosis Step 1. Hold down ON TIMER CANCEL button or OFF TIMER

Strany 69 - G17 – Inverter Y Models

MCQUAY Service Guide Book Diagnosis 70 Error Codes for G17 and GS01 – Inverter Y Models Error Codes Error Descri

Strany 70 - GS01 – Inverter Y Models

MCQUAY Service Guide Book Diagnosis 71 APJ1 –M5WMY10/15KR Indoor LED Indication The operation lamp (green) flashes when any of

Strany 71

MCQUAY Service Guide Book Diagnosis 72 7.3 MDS Diagnosis (A)Indoor Units Model Board Handset A(5)WMD 09/10/15/20/25 G MC201-C G17

Strany 72 - APJ1 –M5WMY10/15KR

MCQUAY Service Guide Book Diagnosis 73 Error Diagnosis by Wired Controller (MC301) ITEM CODE DESCRIPTION 18 F3 Sensor Broken (indoor

Strany 73 - (A)Indoor Units

MCQUAY Service Guide Book Diagnosis 74 (B) Outdoor Units Model Board Handset MDS 30/40/50/60/70 A/AR V4.0 – V4.5 G17/ MC301 MDS 80/

Strany 74

MCQUAY Service Guide Book Diagnosis 75 7.4 General Check When any air conditioner malfunction is noted, immediately switch off the pow

Strany 75 - (B) Outdoor Units

MCQUAY Service Guide Book Diagnosis 76 7.5 General Troubleshooting Guide By means of pressure readings: Pressure Probable Cause Too

Strany 76 - 7.4 General Check

MCQUAY Service Guide Book Appendix 77 APPENDIX A. Resistance – Temperature Characteristics Type DTN-C1 03F3H-OYL 1128, 1148, 11

Strany 77

MCQUAY Service Guide Book Appendix 78 B. MDS Compatibility Indoor PCB vs Wired Handset MC301 MC301 Indoor PCB B1.5 B1.6 B.17 B1.

Strany 78 - APPENDIX

MCQUAY Service Guide Book Handset Operati

Strany 79 - B. MDS Compatibility

MCQUAY Service Guide Book Appendix 79 C. MDS Outdoor Capacity Dip Switch Setting MDS-B PCB version 2.3 and below: Dip Switch S3.1 S3

Strany 80

MCQUAY Service Guide Book Appendix 80 D. Cable Length of Wired Handset No. Wired Handset Cable Type Cable Length (m) Standard Option

Strany 81

©2012 McQuay Internationalwww.mcquayup.com

Strany 82 - ©2012 McQuay International

MCQUAY Service Guide Book Handset Operati